PHYSICAL PROPERTIES OF ZEBRON COATINGS

PROPERTY  

MEASUREMENTS

STANDARDS

Thermal Conductivity  

0.000723 cal./sec.cm2deg.C
Per cm at 20deg. C
(0.175 BTU/HR. ft. deg. F
per ft at 7deg

ASTM C-177
Permeability                                            

.262 gms/24 hr/M2
.0235 metric Perms
.0358 U.S. Perms
.0038 Perms/inch

ASTM E-96

 

SERVICE PROPERTIES OF ZEBRON COATINGS

SERVICE

EFFECT

STANDARDS

Welding steel substrate
Off Gases
                                                               

Under controlled  conditions the
following gas concentrations
obtained from welding ZEBRON
coated steel plate  

Gas Concentration Threshold

Tested (PPM)        Limit (PPM)
CO                                       10 50
CO2                                     0.5  5000
Mixed  NO                          5 25
NO2                                       0.5    5
Phosgene                                 0.1
HCN 1 10

                   

North England Industrial Health Service Report July 1979
Cathodic Disbondment                       1. No effect after 6 weeks in seawater at 1200 mV. No effect after 11 weeks in seawater at 900 mV
2. No effect after 24 days with    2700 micron (106 mil) thick  ZEBRON under 1022 mV in seawater at 25 deg. C.
3. No disbondment after 5 days with 150 mil ZEBRON 5VDC in 5 percent NaCl in glycerol at 300 deg. F. Minor disbondment at side of holiday after 22 days.                          
Netherlands Paint
Research Council TNO
Ignition and Flame Spread                 Index of performance 3.3P. The 3.3 index means a "coating having low flame spread characteristics" and the letter P means "not easily ignitable".
Overall rating was Class 2 by Lloyds meaning ZEBRON coating is acceptable for ships and offshore drilling rigs.
             
Firto, Lloyds Registerof Shipping Certificate No. ICD/F79/223 TE3484 and TE3485
HOME | PHYSICAL | CHEMICAL | TECHNICAL | CONTACT